YIJI

Products/30/300/3000 A AC 3-phase flex current probe TA325
30/300/3000 A AC 3-phase flex current probe TA325

30/300/3000 A AC 3-phase flex current probe TA325

30/300/3000 A AC 3-phase flex current probe TA325, BNC connector

The TA325 is a 3-phase AC current probe utilizing the Rogowski coil principle, used to measure AC current up to 3000 A when used with oscilloscopes, recorders or data loggers. The flexible probe allows current measurements on hard-to-reach conductors. 

Rogowski coil technology has a couple of advantages over CT (current transformer) technology: when measuring multiple phases, the phase difference is small and predictable for higher frequency harmonic analysis applications; also, Rogowski coils do not have magnetic materials to saturate and so have excellent linearity. 

The probes provide a 3 V full-scale AC output proportional to the current being measured with three selectable ranges: 30 A, 300 A and 3000 A. 

When using the TA325 with a PicoScope 4444 differential scope, ensure that you purchase three TA271 D9-BNC adaptors. These can be found under the Accessories tab on this page.

Measuring ranges

30 A / 300 A / 3000 A AC

Output sensitivity (AC coupled)

100 mV / 10 mV / 1 mV per A

Accuracy (45 to 65 Hz)

±1% of reading ±0.1 A 30 / 300 A
±1% of reading ±1 A 3000 A

Minimum load

100 kΩ for specified accuracy

Frequency range

10 Hz to 20 kHz (–1 dB)

Phase (45 to 65 Hz)

< ±1°

Position sensitivity

±2% of reading

External field

±0.25% of range with cable > 100 mm from the probe

Noise

80 mA RMS 30 A
400 mA RMS 300 A / 3000 A

Temperature coefficient

±0.1 % /°C

Power supply

Two AA MN1500 LR6 alkaline batteries or an external power supply (+3 V / 100 mA)

Battery life

1000 hours typical (TA325)
2000 hours typical (TA326)

External power

Via 2.1 mm (0.08") mini power connector

Low battery

Indicated by an orange LED

Overload

Indicated by a red LED

Enclosure

Material

ARNITE T06-200SNF, UL94 V0

Degree of protection

IP40

Dimensions

110 (L) x 65 (W) x 23 (D) mm

Output connection

0.5 m coax cable with 3 shrouded BNC connectors

Probe

Probe length

610 mm (24”), double-insulated

Probe diameter

9.9 mm (0.39”)

Output cable

2 m (78.7”), probe to integrator

Material

Alcryn 2070 NC, LATI LATENE 7H2W V0

Degree of protection

IP65

General characteristics

Operating temperature

–20 °C to +65 °C (–4 °F to +149 °F)

Storage temperature

–40 °C to +75 °C (–40 °F to +167 °F)

Operating humidity

15% to 85% (non-condensing)

Safety standards

EN 61010-1
EN 61010-2-032

EMC

EN 61326-2-2

 

1000 V RMS CAT III, 600 V RMS CAT IV

Pollution Degree 2 (probe and integrator)

30 V maximum between output and ground

RoHS and WEEE compliant

Rated for continuous use